Clamp-on CT's & Flexible Ac Current Probe
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
Models :
M1
|
|
Features :
|
-
Transformer Ratio (Arms) : 100A / 1A
-
Colours : Red, yellow, blue
-
Connection : Safety Sockets for Banana Plugs of 4mm ф
-
Jaw Opening : 15mm ф
-
Conductor Size : 15 mm.Φ
|
|
|
|
|
|
| |
Models :
FLEX-3000A
|
|
Features :
|
-
FLEX - 3000A is designed for accurate measurement of AC, Pulsed DC or complex wave form of very low frequency upto 100kHz.
-
It is very handy to pass through cables or bunches of conductorwires upto a diameter of 170mm (max.) The Clamp-On type Flex 3000 measures the current passing through the conductor. The output through 4mm banana pins can be connected to any Digital Multimeter in mV AC range to read the primary current upto 3000A AC.
|
|
|
|
Range
|
3000A AC
|
|
Accuracy
|
+/- 1%
|
|
Output Terminal
|
4mm Banana Pins
|
|
Output
|
100 mV / 1KA AC
|
|
Probe Length
|
600 mm
|
|
|
| |
Models :
S
|
|
Features :
|
-
Transformer Ratio : 2005A, 500/5A, 1000/5A (Single Range)
100, 500, 1000/5A (Triple Range) -
Output Range: 0 - 5A AC
-
Colours : Red, yellow, blue
-
Connection : Safety Sockets for Banana Plugs of 4mm ф
-
Jaw Opening : 53mm ф
-
Conductor Size : 53mm.Φ
|
|
|
|
|
|
| |
Models :
Caution for all the models
|
|
|
|
Caution
|
The Caution probe secondary should never be open-circuited. Otherwise, lethal voltages will be developed and the probe will be damaged. Always complete teh secondary connection firmly before clipping on the probe to the circuit. For disconnection, reverse the sequence. For power measurements, ensure the correct P1, P2 and S1, S2 polarities as indicated by the arrows on the Probe.
|
|
|
| |
|
|
|
|